Contactar

288V 125A Relay hv bms 3U highly integrated for lfp ncm lto Battery

Precio a convenir
Pedido mínimo: 2 unidades
Tiempo de entrega: 25 días
Envío a: Todo el mundo
Información detallada de

288V 125A Relay hv bms 3U highly integrated for lfp ncm lto Battery

:
Specification:

3U BMS for ESS
192V-600V, 125A-160A
Support multiple BMS in parallel to achieve larger capacity

288V125Amp
Communication protocol:Rs485, CAN, LAN, dry contact, Modbus
* 3U standard 19inch case
* Efficient, stable and reliable
* size:W482*H132*D500mm

Model no.:RBMS07S2-0-250A288V
protecting method:MCCB+Contactor
Rated Current range:-250A~250A
Voltage Range:144V-288V
Current Sampling Accuracy:1.0%FSR
Communication interface with BMU:RS485/CAN
Communication interface with BMU:CAN
Communication interface with BMU:RS485/CAN
Communication with monitoring software/EMS:Ethernet
Support IAP upgrade:Yes
Support HMI display and parameter:No(Optional plug in)
Insulation detection:Yes(Optional)
High voltage power module:Support DC start (optional)
Dry contact output (normally open):No
Maximum qty of BMUs:20
Power:24VDC(18~28V)
Power consumption:≤20W
Size(W*H*D)mm:4U (440*178*600)
Way out:Front
Center Tap:Support(Optional)
Net weight:23kg


Safety Precautions:

1.Tools for installation and commissioning personnel must be insulated
2.Insulation rubber gloves must be worn during the installation and maintenance. Wear goggles and insulating rubber Boots as the case may be to avoid the possible safety accidents.
3.Installation, commissioning and maintenance of the thread metal generated in the process, such as dropped into the battery, be sure to use an insulating tool to remove, you can not be lingering debris.
4.When maintenance is required, the main circuit breaker of the CBMS must be disconnected to cut off the connection of the battery pack to the PCS DC bus.
5.According to project requirements, parameters such as charge and discharge current and charge and discharge voltage of the battery management system have been set during initial.
6.Document number installation and debugging. Parameters may not be changed without authorization. Otherwise, the battery life may be shortened, and more serious battery may be damaged Cause serious harm to safety accidents
7.In case of fire around the energy storage cabinet, be sure to use dry powder fire extinguishers or fire extinguishing sand. Fire extinguishing with liquid may cause electric shock.
8.If the system is not used for a long time, be sure to disconnect the main circuit breaker of the battery cabinet
9.Try to avoid long-term use in the following working environment:
10.Exceeds the temperature or humidity range specified in the specification
11.Strong vibration or vulnerable to impact of the place
12.Direct sunlight or near the heat source of the place
13.Dust, corrosive substances, flammable, high salt spray place

Vídeo

288V 125A Relay BMS 16S HV Master BMS Home Energy Management System Advanced Battery Management System --- The highly integrated battery management system enables seamless monitoring. Perfect self-test and operational status detection, with HMI display, system operation information at a glance. Perfect and reliable system control and protection strategies to fully protect the battery safety, extend the life of the battery escort. Modular design, configurable, scalable --- flexible combination of multiple energy storage unit Can be expanded to a larger energy storage system, the maximum can support 272 (lead-carbon battery 400) battery series. Rich communication interface --- multiple RS485, CAN, Ethernet, dry contact input and output interfaces, support for most of the market with PCS, monitoring server communication. Capacity is large --- Built-in large-capacity memory chips can store a large number of key operational data, but also can install an SD card for offline access. PCS has a protocol control function, the choice of circuit breaker version . PCS without protocol control function, the choice of contactor + breaker version. Automatic circulation control and automatic parallel machine off-line control, can be easily Parallel battery. (Model suffix selection D). Application Scenarios ◎ Battery Energy Storage System(BESS) ◎ Off-grid energy storage ◎ Data Center ◎ Grid frequency modulation energy storage ◎ Track power / traction ◎ LFP UPS power supply Our comapny We are a company with many years experience in Battery Management Systems, making them work for our customers, ensuring that their systems are operating with greater efficiency and therefore benefit from optimum energy performance and increased comfort levels. We utilise intelligent programming and our skilled engineering team are trained to understand how to achieve this. No separate energy monitoring system or complex interface required. BMS staff are very knowledgeable and approachable and can diagnose problems quickly. They are very professional in communication issues to us and our clients. Contact with: Jojoling Weng Marketing Director wenglin@hngce.com 0086-15570747076

integrated bms rs485 lifepo4 ups bms nmc integrated bms oem ups bms relay ess bms